Cool the AI era with up to 90% less cooling energy

GRC single-phase immersion cooling submerges your servers in a safe, non-conductive fluid that captures 100% of their heat. It brings Egypt's hottest, densest compute under control. TDS supplies, designs and supports it locally.

● Live demo: ICEraQ Pico at the Raya IT booth Egypt · Saudi Arabia delivery
<1.03pPUE
Cooling overhead, ICEraQ SX
184kW
Per rack, ICEraQ SX
100%
Of heat captured by fluid
~3months
Typical deployment time
Live at Cairo ICT 2026

Lift the lid on immersion cooling at the Raya IT booth

We've put a working GRC ICEraQ Pico on the Raya IT stand. Come and look into the tank, see servers running fully submerged, and ask our data-center team how the same technology scales from one demo unit to a multi-megawatt AI hall.

5UImmersion-cooled rack space
3.5 kWCooling capacity
2 × 1UAir-cooled space for switches and PDUs
Plug and playPower, a level floor, indoor air below 35°C
Book a meeting at the booth
GRC ICEraQ Pico immersion cooling demonstrator at an event
At the booth: GRC ICEraQ Pico, 3.5 kW demonstrator
GRC ICEraQ SX Duo immersion cooling system
From the booth to the data hall

Same technology, full scale: the ICEraQ SX Duo

The Pico on our stand runs the same single-phase immersion cooling as GRC's ICEraQ SX Duo, built for enterprise and AI halls.

2 × 42UImmersion racks
184 kWPer rack, 13°C water
<1.03Partial PUE
TDS – Talents Digital Services GRC – Green Revolution Cooling Raya Information Technology
Watch

TDS × GRC: immersion cooling for Egypt's AI era

A short film on why TDS partnered with GRC, and what you'll see at the Raya IT booth.

Watch on YouTube ↗

The challenge

Cooling has become the bottleneck for AI in our region

AI accelerators run hotter every generation. In a 40–50°C summer, air cooling burns power and water that should be going to compute.

40–50°C

Ambient heat

MENA summers push chillers and CRAC units to their limits, driving up cooling cost and risk.

>50 kW

Rack density

Modern GPU racks outgrow what air can remove. Air-cooled halls typically stall below 20 kW per rack.

~70%

Energy lost to cooling

In a typical air-cooled facility, cooling adds close to 70% on top of the IT load. Immersion brings it to about 3%.

How it works

One simple loop, from chip to dry cooler

  1. Servers are submerged

    ElectroSafe® dielectric fluid flows up from the bottom of the rack through the servers and absorbs all of their heat. Server fans are removed.

  2. The CDU moves the heat

    Warm fluid passes through the rack's integrated heat exchanger. Only two moving parts in normal operation: one pump and one control valve.

  3. Water rejects or reuses it

    A facility water loop carries the heat to a dry cooler or chiller, or to reuse as hot water. Supply water can run warm (40°C) or cold (13°C).

No CRAC/CRAH unitsNo raised floorNo humidity control65–70 dB at the rack15+ year system life
Cut-away of a GRC immersion rack showing the fluid loop and heat exchanger
Same compute, less of everything else

1,000 kW of compute: 1,700 kW with air, 1,030 kW with immersion

The 670 kW difference isn't just a smaller electricity bill. It's UPS capacity, generators and switchgear you don't have to buy. In an existing hall, it's power you already pay for that goes back to compute.

Legacy air-cooled hall: 1700 kW of power for 1000 kW of compute
Legacy air. Rows of CRAC units, generators sized for 1.7 MW.
Immersion-cooled hall: 1030 kW of power for 1000 kW of compute
GRC immersion. The same compute in a fraction of the room, on 1.03 MW.
MetricAir coolingGRC immersion
Rack density<20 kWUp to 184 kW (ICEraQ SX)
Cooling energyBaselineUp to 90% less
PUE / pPUE~1.70<1.03 pPUE
Server power drawFans included~11% lower (fans removed)
Heat captured60–70% even with direct-to-chip100%
Build costCRACs, raised floor, chillersUp to 50% lower

Figures as published by GRC (GRC Overview 2026, ICEraQ SX datasheet). Actual results vary by site, hardware and design.

The GRC portfolio

One platform, from the desk to the desert

Every GRC system shares the same fluid, controls and monitoring, so a pilot grows into production without starting over.

ICEraQ Nano

ICEraQ Nano

10U · liquid-to-air

Edge rack that needs no chilled water at all.

ICEraQ Micro

ICEraQ Micro

24U · 45–90 kW

Compact system with integrated CDU for edge and evaluation.

GRC ICEraQ SX Duo immersion cooling system

ICEraQ SX Duo / Quad

42U · up to 184 kW/rack

Enterprise and AI halls, with a 2N CDU option.

GRC ICEtank containerized data center

ICEtank

Containerized DC

A modular data center for a parking lot, desert site or remote edge.

Proven in production

Running today in some of the world's most demanding environments

GRC has installations in more than 20 countries and runs the longest-running immersion cooling installation in the world.

U.S. Air Force

Containerized edge deployment

  • 93.1% less cooling power
  • 314% more power per rack
  • 18.1% lower server draw (no fans)
  • One ISO module = 153 air-cooled racks
TACC Lonestar6

Hybrid supercomputer

  • 500+ Dell nodes immersed
  • Cooling PUE ~1.02
  • 99.47% annual reliability on Nvidia GPUs
  • No conductive-fluid risk
Energy sector

1.2 MW AI data center

  • Eight ICEraQ Series 10 Duo systems
  • 150 kW cooled per rack
  • PUE 1.02
  • Shell ElectroSafe® fluids

GRC customer references

Results and references as published by GRC on grcooling.com and in its case studies. Names are listed for reference only and do not imply endorsement of TDS.

GRC immersion tanks filled with Shell immersion cooling fluid
GRC – Green Revolution Cooling Why GRC

The immersion cooling authority

Green Revolution Cooling, founded in 2009 in Austin, Texas, built the first rack-based immersion cooling system. It still leads the market in single-phase immersion.

2009First rack-based immersion provider
65Patents, 25 more pending
20+Countries with installations
ISO 90012015-certified quality system

Strategic alliances with Dell, HPE, Cisco, Schneider, Shell, Castrol, Petronas and Park Place Technologies. In GRC's own partner network, TDS is the authorized solution partner for Egypt. grcooling.com ↗

Why TDS

Data-center depth, ICT delivery muscle

Immersion cooling is a facility decision, an IT decision and an operations decision at once. TDS brings all three.

28 years

At IBM, most of them inside the data center

TDS's founders built their careers in hardware, software, networking, and data-center facility design and build, and are among the few recognized data-center experts in Egypt. That experience is behind TDS's immersion cooling practice, so every GRC project starts from real facility knowledge, not a brochure.

The TDS foundersTDS: Talents Digital Services
Data centers our founders helped build
WE
WETelecom Egypt
OR
OrangeEgypt
BM
Banque MisrBanking · Egypt
SIO
SIOEgypt
MO
MobilyTelecom · Saudi Arabia
+
Your data center nextRetrofit or new build

DC assessment & design

Site survey, power and water baseline, TCO model and immersion design for retrofit, hybrid or greenfield.

TDS ICT-ERP

Our bid-to-cash platform for ICT integrators and telecom contractors, proven at ECOTEL Holding and LTS.

AI & monitoring

Dashboards, alerting and predictive insight on top of GRC's telemetry, built by our AI division.

Managed services

Ongoing support and optimization. With Raya IT for site engineering, deployment and data-center build.

How we engage

From first conversation to a running immersion hall

1

Assess

Site visit, load profile and a TCO comparison against your current cooling.

2

Pilot

A Pico or Micro running your own servers in your own hall.

3

Deploy

Design, supply and install with GRC engineering and Raya IT infrastructure teams.

4

Operate

Monitoring, support and expansion in 25 kW steps as demand grows.

Let's talk

Meet us at Cairo ICT 2026, or bring us to your data center

Visit the Raya IT booth to see the ICEraQ Pico live, or book a site assessment with the TDS data-center team.

Request an assessment Explore grcooling.com ↗